998 resultados para buffer storage


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Large-grain synchronous dataflow graphs or multi-rate graphs have the distinct feature that the nodes of the dataflow graph fire at different rates. Such multi-rate large-grain dataflow graphs have been widely regarded as a powerful programming model for DSP applications. In this paper we propose a method to minimize buffer storage requirement in constructing rate-optimal compile-time (MBRO) schedules for multi-rate dataflow graphs. We demonstrate that the constraints to minimize buffer storage while executing at the optimal computation rate (i.e. the maximum possible computation rate without storage constraints) can be formulated as a unified linear programming problem in our framework. A novel feature of our method is that in constructing the rate-optimal schedule, it directly minimizes the memory requirement by choosing the schedule time of nodes appropriately. Lastly, a new circular-arc interval graph coloring algorithm has been proposed to further reduce the memory requirement by allowing buffer sharing among the arcs of the multi-rate dataflow graph. We have constructed an experimental testbed which implements our MBRO scheduling algorithm as well as (i) the widely used periodic admissible parallel schedules (also known as block schedules) proposed by Lee and Messerschmitt (IEEE Transactions on Computers, vol. 36, no. 1, 1987, pp. 24-35), (ii) the optimal scheduling buffer allocation (OSBA) algorithm of Ning and Gao (Conference Record of the Twentieth Annual ACM SIGPLAN-SIGACT Symposium on Principles of Programming Languages, Charleston, SC, Jan. 10-13, 1993, pp. 29-42), and (iii) the multi-rate software pipelining (MRSP) algorithm (Govindarajan and Gao, in Proceedings of the 1993 International Conference on Application Specific Array Processors, Venice, Italy, Oct. 25-27, 1993, pp. 77-88). Schedules generated for a number of random dataflow graphs and for a set of DSP application programs using the different scheduling methods are compared. The experimental results have demonstrated a significant improvement (10-20%) in buffer requirements for the MBRO schedules compared to the schedules generated by the other three methods, without sacrificing the computation rate. The MBRO method also gives a 20% average improvement in computation rate compared to Lee's Block scheduling method.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

To investigate the effects of adopting a pull system in assembly lines in contrast to a push system, simulation software called “ARENA” is used as a tool in order to present numerical results from both systems. Simulation scenarios are created to evaluate the effects of attributes changing in assembly systems, with influential factors including the change of manufacturing system (push system to pull system) and variation of demand. Moreover, pull system manufacturing consists of the addition attribute, which is the number of buffer storage. This paper will provide an analysis based on a previous case study, hence process time and workflow refer to the journal name “Optimising and simulating the assembly line balancing problem in a motorcycle manufacturing company: a case study” [2]. The implementation of the pull system mechanism is to produce a system improvement in terms of the number of Work-In-Process (WIP), total time of products in the system, and the number of finished product inventory, while retaining the same throughput.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper proposes a practical and cost-effective approach to construct a fully distributed roadside communication infrastructure to facilitate the localized content dissemination to vehicles in the urban area. The proposed infrastructure is composed of distributed lightweight low-cost devices called roadside buffers (RSBs), where each RSB has the limited buffer storage and is able to transmit wirelessly the cached contents to fast-moving vehicles. To enable the distributed RSBs working toward the global optimal performance (e.g., minimal average file download delays), we propose a fully distributed algorithm to determine optimally the content replication strategy at RSBs. Specifically, we first develop a generic analytical model to evaluate the download delay of files, given the probability density of file distribution at RSBs. Then, we formulate the RSB content replication process as an optimization problem and devise a fully distributed content replication scheme accordingly to enable vehicles to recommend intelligently the desirable content files to RSBs. The proposed infrastructure is designed to optimize the global network utility, which accounts for the integrated download experience of users and the download demands of files. Using extensive simulations, we validate the effectiveness of the proposed infrastructure and show that the proposed distributed protocol can approach to the optimal performance and can significantly outperform the traditional heuristics.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A CMOS memory-cell for dynamic storage of analog data and suitable for LVLP applications is proposed. Information is memorized as the gate-voltage of input-transistor of a gain-boosting triode-transconductor. The enhanced output-resistance improves accuracy on reading out the sampled currents. Additionally, a four-quadrant multiplication between the input to regulation-amplifier of the transconductor and the stored voltage is provided. Designing complies with a low-voltage 1.2μm N-well CMOS fabrication process. For a 1.3V-supply, CCELL=3.6pF and sampling interval is 0.25μA≤ ISAMPLE ≤ 0.75μA. The specified retention time is 1.28ms and corresponds to a charge-variation of 1% due to junction leakage @75°C. A range of MR simulations confirm circuit performance. Absolute read-out error is below O.40% while the four-quadrant multiplier nonlinearity, at full-scale is 8.2%. Maximum stand-by consumption is 3.6μW/cell.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Design of a battery energy storage system (BESS) in a buffer scheme is examined for the purpose of attenuating the effects of unsteady input power from wind farms. The design problem is formulated as maximization of an objective function that measures the economic benefit obtainable from the dispatched power from the wind farm against the cost of the BESS. Solution to the problem results in the determination of the capacity of the BESS to ensure constant dispatched power to the connected grid, while the voltage level across the dc-link of the buffer is kept within preset limits. A computational procedure to determine the BESS capacity and the evaluation of the dc voltage is shown. Illustrative examples using the proposed design method are included.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper examines a buffer scheme to mitigate the negative impacts of power-conditioned loads on network voltage and transient stabilities. The scheme is based on the use of battery energy-storage systems in the buffers. The storage systems ensure that protected loads downstream of the buffers can ride through upstream voltage sags and swells. Also, by controlling the buffers to operate in either constant impedance or constant power modes, power is absorbed or injected by the storage systems. The scheme thereby regulates the rotor-angle deviations of generators and enhances network transient stability. A computational method is described in which the capacity of the storage systems is determined to achieve simultaneously the above dual objectives of load ride-through and stability enhancement. The efficacy of the resulting scheme is demonstrated through numerical examples.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In questa tesi sono stati studiati i fattori che influenzano l'utilizzo del buffer in un magazzino manuale. Per poter realizzare le analisi è stato realizzato un programma C# che simula la gestione del magazzino. Per ottimizzare l'assegnamento dei pallet alle location si è inoltre costruito un modello AMPL. L'obiettivo del modello è minimizzare la differenza tra le classi ottime dei codici in ingresso e i posti pallet ai quali questi vengono assegnati. Il programma C# oltre all'interfaccia con il risolutore AMPL Gurobi, deve interfacciarsi anche con il data base Access nel quale sono stati organizzati i dati necessari per l'analisi. Questi dati sono reali e relativi agli ingressi e alle uscite di un magazzino contenente materiale farmaceutico di due settimane di lavoro. Per facilitare e velocizzare lo studio le informazioni considerate sono quelle di due soli corridoi e non dell'intero magazzino. I risultati hanno evidenziato quattro fattori principali che influenzano la differenza tra un l'allocazione dei pallet in ingresso ad un magazzino. Questi elementi sono: costo di utilizzo del buffer, numero di location libere ad inizio simulazione, momento d'esecuzione del picking a magazzino e tipologia di location vute ad inizio della simulazione. Per ognuno di questi si è cercato, per quanto possibile, di individuare le implicazioni che quanto studiato può avere nella progettazione di un sistema di stoccaggio reale sia dal punto di vista logistico sia dal punto di vista economico. Non sempre le osservazioni reali alle quali si è arrivati hanno un risvolto pratico immediato, ma senza dubbio possono essere utili nello studio preliminare per la realizzazione di un sistema di stoccaggio. All'interno delle conclusioni sono state inserite anche possibili studi e approfondimenti futuri che possono essere eseguiti partendo dal progetto di tesi qui presentato.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Electrification of vehicular systems has gained increased momentum in recent years with particular attention to constant power loads (CPLs). Since a CPL potentially threatens system stability, stability analysis of hybrid electric vehicle with CPLs becomes necessary. A new power buffer configuration with battery is introduced to mitigate the effect of instability caused by CPLs. Model predictive control (MPC) is applied to regulate the power buffer to decouple source and load dynamics. Moreover, MPC provides an optimal tradeoff between modification of load impedance, variation of dc-link voltage and battery current ripples. This is particularly important during transients or starting of system faults, since battery response is not very fast. Optimal tradeoff becomes even more significant when considering low-cost power buffer without battery. This paper analyzes system models for both voltage swell and voltage dip faults. Furthermore, a dual mode MPC algorithm is implemented in real time offering improved stability. A comprehensive set of experimental results is included to verify the efficacy of the proposed power buffer.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A power electronics-based buffer is examined in which through control of its PWM converters, the buffer-load combination is driven to operate under either constant power or constant impedance modes. A battery, incorporated within the buffer, provides the energy storage facility to facilitate the necessary power flow control. Real power demand from upstream supply is regulated under fault condition, and the possibility of voltage or network instability is reduced. The proposed buffer is also applied to a wind farm. It is shown that the buffer stabilizes the power contribution from the farm. Based on a battery cost-benefit analysis, a method is developed to determine the optimal level of the power supplied from the wind farm and the corresponding capacity of the battery storage system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

CD-ROMs have proliferated as a distribution media for desktop machines for a large variety of multimedia applications (targeted for a single-user environment) like encyclopedias, magazines and games. With CD-ROM capacities up to 3 GB being available in the near future, they will form an integral part of Video on Demand (VoD) servers to store full-length movies and multimedia. In the first section of this paper we look at issues related to the single- user desktop environment. Since these multimedia applications are highly interactive in nature, we take a pragmatic approach, and have made a detailed study of the multimedia application behavior in terms of the I/O request patterns generated to the CD-ROM subsystem by tracing these patterns. We discuss prefetch buffer design and seek time characteristics in the context of the analysis of these traces. We also propose an adaptive main-memory hosted cache that receives caching hints from the application to reduce the latency when the user moves from one node of the hyper graph to another. In the second section we look at the use of CD-ROM in a VoD server and discuss the problem of scheduling multiple request streams and buffer management in this scenario. We adapt the C-SCAN (Circular SCAN) algorithm to suit the CD-ROM drive characteristics and prove that it is optimal in terms of buffer size management. We provide computationally inexpensive relations by which this algorithm can be implemented. We then propose an admission control algorithm which admits new request streams without disrupting the continuity of playback of the previous request streams. The algorithm also supports operations such as fast forward and replay. Finally, we discuss the problem of optimal placement of MPEG streams on CD-ROMs in the third section.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Photoassisted electrolysis of water is considered as an effective way of storing solar energy in the form of hydrogen fuel. This overall reaction involves the oxidation of water to oxygen at the anode and the reduction of protons to hydrogen at the cathode. Cobalt-phosphate-based catalyst (Co-Pi) is a potentially useful material for oxygen evolution reaction. In the present study, electrochemical deposition of Co-Pi catalyst is carried out on Au-coated quartz crystal from 0.1 M phosphate buffer (pH 7) containing 0.5 mM Co2+ ion, along with the simultaneous measurement of mass changes at the electrode surface. Cyclic voltammograms and mass variations are recorded during the course of deposition. A current peak is observed at 0.92 V vs Ag/AgCl, 3 M KCl corresponding to oxidation of Co2+ ion. The mass of the electrode starts increasing at this potential, suggesting the deposition of a Co(III)-based insoluble product on the electrode surface. The stability of the catalyst is also studied at several potentials in both buffered and nonbuffered electrolyte by monitoring the real-time mass variations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We have investigated the spectra of the electromagnetically induced transparency (EIT) when a cell is filled with a buffer gas. Our theoretical results show that the buffer gas can induce a narrower spectra line and steeper dispersion than those of the usual EIT case in a homogeneous and Doppler broadened system. The linewidth decreases with the increase of the buffer gas pressure. This narrow spectra may be applied to quantum information processing, nonlinear optics and atomic frequency standard.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: Peptide YY (PYY) is a gastrointestinal hormone with physiological actions regulating appetite and energy homoeostasis. The cellular mechanisms by which nutrients stimulate PYY secretion from intestinal enteroendocrine cells are still being elucidated.

METHODS: This study comprehensively evaluated the suitability of intestinal STC-1 cells as an in vitro model of PYY secretion. PYY concentrations (both intracellular and in culture media) with other intestinal peptides (CCK, GLP-1 and GIP) demonstrated that PYY is a prominent product of STC-1 cells. Furthermore, acute and chronic PYY responses to 15 short (SCFAs)- and long-chain (LCFAs) dietary fatty acids were measured alongside parameters for DNA synthesis, cell viability and cytotoxicity.

RESULTS: We found STC-1 cells to be reliable secretors of PYY constitutively releasing PYY into cell culture media (but not into non-stimulatory buffer). We demonstrate for the first time that STC-1 cells produce PYY mRNA transcripts; that STC-1 cells produce specific time- and concentration-dependent PYY secretory responses to valeric acid; that linoleic acid and conjugated linoleic acid 9,11 (CLA 9,11) are potent PYY secretagogues; and that chronic exposure of SCFAs and LCFAs can be detrimental to STC-1 cells.

CONCLUSIONS: Our studies demonstrate the potential usefulness of STC-1 cells as an in vitro model for investigating nutrient-stimulated PYY secretion in an acute setting. Furthermore, our discovery that CLA directly stimulates L-cells to secrete PYY indicates another possible mechanism contributing to the observed effects of dietary CLA on weight loss.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The work presented in this thesis concerns the dimensioning of an Energy Storage System (ESS) which will be used as an energy buffer for a grid-connected PV plant. This ESS should help managing the PV plant to inject electricity into the grid according to the requirements of the grid System Operator. It is desired to obtain a final production not below 1300kWh/kWp with a maximum ESS budget of 0.9€/Wp. The PV plant will be sited in Martinique Island and connected to the main grid. This grid is a small one where the perturbations due clouds in the PV generation are not negligible anymore. A software simulation tool, incorporating a model for the PV-plant production, the ESS and the required injection pattern of electricity into the grid has been developed in MS Excel. This tool has been used to optimize the relevant parameters defining the ESS so that the feed-in of electricity into the grid can be controlled to fulfill the conditions given by the System Operator. The inputs used for this simulation tool are, besides the conditions given by the System Operator on the allowed injection pattern, the production data from a similar PV-plant in a close-by location, and variables for defining the ESS. The PV production data used is from a site with similar climate and weather conditions as for the site on the Martinique Island and hence gives information on the short term insolation variations as well as expected annual electricity production. The ESS capacity and the injected electric energy will be the main figures to compare while doing an economic study of the whole plant. Hence, the Net Present Value, Benefit to Cost method and Pay-back period studies are carried on as dependent of the ESS capacity. The conclusion of this work is that it is possible to obtain the requested injection pattern by using an ESS. The design of the ESS can be made within an acceptable budget. The capacity of ESS to link with the PV system depends on the priorities of the final output characteristics, and it also depends on which economic parameter that is chosen as a priority.